FUNCTIONS FOR RECEIVE | 5 |
CW ( – 500Hz) | SHARP |
Select the filter shape for CW mode in HF bands.
The set filter shape is automatically used only when the IF filter is set to 500 Hz or narrower.
CW (600Hz – ) | SHARP |
Select the filter shape for CW mode in HF bands.
The set filter shape is automatically used only when the IF filter is set to 600 Hz or wider.
50M SSB (600Hz – ) | SOFT |
Select the filter shape for SSB mode in 50 MHz band.
The set filter shape is automatically used only when the IF filter is set to 600 Hz or wider.
SHARP |
Select the filter shape for SSB data mode in 50 MHz band.
The set filter shape is automatically used only when the IF filter is set to 600 Hz or wider.
CW ( – 500Hz) | SHARP |
Select the filter shape for CW mode in 50 MHz band.
The set filter shape is automatically used only when the IF filter is set to 500 Hz or narrower.
CW (600Hz – ) | SHARP |
Select the filter shape for CW mode in 50 MHz band.
The set filter shape is automatically used only when the IF filter is set to 600 Hz or wider.