5 FUNCTIONS FOR RECEIVE

DMini scope screen indication

M.SCOPE

DScope set mode

Ω ≈

WIDE

F-3

F-7

DEF

EXIT/SET Main dial

F-1 F-2 F-4

The mini scope screen can be displayed with another screen display, such as set mode menu, decode screen, memory list screen, etc. simultaneously.

qSet the scope mode (center or fixed), marker, at- tenuator, span, etc. in advance. (pgs. 5-2, 5-3)

wPush M.SCOPE to toggle the mini scope indication ON and OFF.

The S/RF meter type during mini scope indication can be selected in display set mode (Meter Type (Wide Screen) item). (p. 12-10)

This set mode is used to set the waveform color, sweeping speed, scope range for fixed mode, etc.

qDuring spectrum scope display ON, push [F-7•SET] to select scope set mode screen.

Push [F-7•WIDE] to toggle the screen size between nor- mal and wide.

wPush [F-1•Y] or [F-2•Z] to select the desired set item.

eSet the desired condition using the main dial.

Push and hold [F-4•DEF] for 1 sec. to select the default condition or value.

Push [F-3•] to select the set contents for some items.

r Push EXIT/SET to exit from set mode.