14 CONTROL COMMAND

DOffset frequency setting

The following data sequence is used when sending or reading the offset frequency setting.

 

 

q

 

 

w

 

 

e

r*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X

0

X

X

0

X

XX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100 Hz digit: 0 (fixed)

 

 

 

 

 

 

 

 

 

 

 

 

100 kHz digit: 0–9

10 kHz digit: 0–9

10 MHz digit: 0–9

1 MHz digit: 0–4

 

 

1 kHz digit: 0–9

 

 

Direction: 00=+ direction 01=– direction

*No need to enter for transverter offset frequency setting.

Transverter offset only; Fix to ‘0’ for split offset setting.

DRepeater tone/tone squelch frequency setting

The following data sequence is used when sending or reading the tone frequency setting.

 

q*

 

 

 

w

 

 

 

 

e

 

 

 

 

 

 

 

 

 

 

 

 

0

0

X

X

X

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100Hz digit: 0–2

10 Hz digit: 0–9

 

 

0.1 Hz digit: 0–9

 

 

 

 

1 Hz digit: 0–9

Fixed digit: 0*

Fixed digit: 0*

*Not necessary when setting a frequency.

DSSB transmission passband width setting

The following data sequence is used when sending or reading the SSB transmission passband width setting.

X X

Lower edge: 0=100 Hz 1=200 Hz 2=300 Hz 3=500 Hz

Higher edge: 0=2500 Hz 1=2700 Hz 2=2800 Hz 3=2900 Hz

DColor setting

The following data sequence is used when sending or reading the color setting.

 

 

q

 

w

 

 

e

 

 

r

 

 

t

 

 

y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

X

X X

0

X

X X

0 X

X

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1000

 

 

 

 

 

 

 

1000

 

 

 

 

 

 

 

1000

 

 

 

 

 

 

 

100

 

 

 

 

 

100

 

 

 

 

 

100

 

 

 

 

 

10

 

 

 

10

 

 

 

10

 

 

 

1

 

1

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R (Red)

 

 

 

 

 

G (Green)

 

 

B (Blue)

Using 0000–0255 for each color element.

DBandscope edge frequency setting

The following data sequence is used when sending or reading the bandscope edge frequency setting.

 

 

 

q

 

 

w

e

 

 

 

r

 

 

t

y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X X

X

X

X X

 

X X

X

X

X X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100 Hz: 0 (fixed)

 

 

 

 

 

 

 

 

 

 

100 Hz: 0 (fixed)

 

 

 

 

 

 

 

 

1 kHz: 0–9

100 kHz: 0–9

10 kHz: 0–9 10 MHz: 0–6

1 MHz: 0–9

 

1 kHz: 0–9

100 kHz: 0–9

10 kHz: 0–9 10 MHz: 0–6

1 MHz: 0–9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lower edge

 

 

 

 

 

Higher edge

 

 

DData mode with filter width setting

The following data sequence is used when sending or reading the data mode with filter width setting.

qw

X X X X

00=Data mode OFF 01=FIL1 02=FIL2 03=FIL3

00=Data mode OFF 01=Data mode 1 (D1) 02=Data mode 2 (D2) 03=Data mode 3 (D3)

DAntenna memory setting

The following codes are used when sending or reading the antenna memory setting.

0=ANT1, 1=ANT2, 2=ANT3, 3=ANT4,

4*=TX: ANT1, RX: ANT4, 5*=TX: ANT2, RX: ANT4,

6*=TX: ANT3, RX: ANT4

*RX should be selected for ANT4

14-10