14 CONTROL COMMAND
DOffset frequency settingThe following data sequence is used when sending or reading the offset frequency setting.
|
| q |
|
| w |
|
| e | r* | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X | 0 | X | X | 0 | X | XX | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 100 Hz digit: 0 (fixed) |
|
|
|
|
|
|
|
|
|
| |
|
| 100 kHz digit: | 10 kHz digit: | 10 MHz digit: | 1 MHz digit: |
|
| ||||||
1 kHz digit: |
|
| |||||||||||
Direction: 00=+ direction 01=– direction |
*No need to enter for transverter offset frequency setting.
†Transverter offset only; Fix to ‘0’ for split offset setting.
DRepeater tone/tone squelch frequency settingThe following data sequence is used when sending or reading the tone frequency setting.
| q* |
|
|
| w |
|
|
|
| e | |
|
|
|
|
|
|
|
|
|
|
|
|
0 | 0 | X | X | X | X | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 100Hz digit: | 10 Hz digit: |
|
| 0.1 Hz digit: | |||
|
|
|
| 1 Hz digit: | |||||||
Fixed digit: 0* | Fixed digit: 0* |
*Not necessary when setting a frequency.
DSSB transmission passband width settingThe following data sequence is used when sending or reading the SSB transmission passband width setting.
X X
Lower edge: 0=100 Hz 1=200 Hz 2=300 Hz 3=500 Hz
Higher edge: 0=2500 Hz 1=2700 Hz 2=2800 Hz 3=2900 Hz
The following data sequence is used when sending or reading the color setting.
|
| q |
| w |
|
| e |
|
| r |
|
| t |
|
| y | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
0 | X | X X | 0 | X | X X | 0 X | X | X | ||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1000 |
|
|
|
|
|
|
| 1000 |
|
|
|
|
|
|
| 1000 |
|
|
|
|
|
|
| |||
100 |
|
|
|
|
| 100 |
|
|
|
|
| 100 |
|
|
|
|
| |||||||||
10 |
|
|
| 10 |
|
|
| 10 |
|
|
| |||||||||||||||
1 |
| 1 |
| 1 |
| |||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||
|
| R (Red) |
|
|
|
|
| G (Green) |
|
| B (Blue) |
Using
The following data sequence is used when sending or reading the bandscope edge frequency setting.
|
|
| q |
|
| w | e |
|
|
| r |
|
| t | y | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
| X X | X | X | X X |
| X X | X | X | X X | ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
| 100 Hz: 0 (fixed) |
|
|
|
|
|
|
|
|
|
| 100 Hz: 0 (fixed) |
|
|
|
|
|
|
| ||||
| 1 kHz: | 100 kHz: | 10 kHz: | 1 MHz: |
| 1 kHz: | 100 kHz: | 10 kHz: | 1 MHz: | ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||
|
|
|
| Lower edge |
|
|
|
|
| Higher edge |
|
|
The following data sequence is used when sending or reading the data mode with filter width setting.
qw
X X X X
00=Data mode OFF 01=FIL1 02=FIL2 03=FIL3
00=Data mode OFF 01=Data mode 1 (D1) 02=Data mode 2 (D2) 03=Data mode 3 (D3)
DAntenna memory settingThe following codes are used when sending or reading the antenna memory setting.
0=ANT1, 1=ANT2, 2=ANT3, 3=ANT4,
4*=TX: ANT1, RX: ANT4, 5*=TX: ANT2, RX: ANT4,
6*=TX: ANT3, RX: ANT4
*RX should be selected for ANT4