AGC function

[AGC] control AGC VR AGC

DSelecting the preset valueDAdjusting the AGC time constant

FUNCTIONS FOR RECEIVE

5

The AGC (auto gain control) controls receiver gain to produce a constant audio output level even when the received signal strength varies greatly.

The transceiver has 3 preset AGC characteristics (time constant: fast, mid, slow) for non-FM mode.

The FM mode AGC time constant is fixed as ‘FAST’ (0.1 sec.) and AGC time constant cannot be changed.

qSelect any non-FM mode.

wPush [AGC] (MF5) several times to select AGC fast,

AGC medium (MID) or AGC slow.

• Push and hold AGC VR for 1 sec. to turn the AGC function OFF.

qSelect any non-FM mode.

wPush AGC VR , then rotate [AGC] control to adjust the AGC time constant.

• [AGC VR] indicator above the switch lights green.

DSetting the AGC time constant preset value
• Selectable AGC time constant

(unit: sec.)

Mode

Default

Selectable AGC time constant

 

0.3

(FAST)

0.1, 0.2, 0.3, 0.5, 0.8, 1.2, 1.6, 2.0,

SSB

2.0

(MID)

2.5, 3.0, 4.0, 5.0, 6.0

 

 

6.0

(SLOW)

 

 

 

 

 

 

 

0.1

(FAST)

0.1, 0.2, 0.3, 0.5, 0.8, 1.2, 1.6, 2.0,

CW

0.5

(MID)

2.5, 3.0, 4.0, 5.0, 6.0

 

 

1.2

(SLOW)

 

 

 

 

 

RTTY

0.1

(FAST)

0.1, 0.2, 0.3, 0.5, 0.8, 1.2, 1.6, 2.0,

0.5

(MID)

PSK

2.5, 3.0, 4.0, 5.0, 6.0

 

 

 

 

1.2

(SLOW)

 

 

 

 

 

 

 

3.0

(FAST)

0.3, 0.5, 0.8, 1.2, 1.6, 2.0, 2.5, 3.0,

 

 

 

AM

5.0

(MID)

4.0, 5.0, 6.0, 7.0, 8.0

 

 

 

 

 

 

7.0

(SLOW)

 

 

 

 

 

 

FM

0.1

(FAST)

Fixed

 

 

 

 

 

 

qSelect any non-FM mode.

wPush and hold [AGC] (MF5) for 1 sec. to enter AGC set mode.

ePush [AGC] (MF5) several times to select FAST time constant.

rRotate the main dial to set the desired time constant for ‘AGC FAST.’

AGC time constant can be set between 0.1 to 8.0 sec. (depends on mode) or turned OFF.

Push and hold [F-4•DEF] for 1 sec. to select a default value.

tPush [AGC] (MF5) to select medium time constant. yRotate the main dial to set the desired time constant

for ‘AGC MID.’

AGC time constant can be set between 0.1 to 8.0 sec. (depends on mode) or turned OFF.

Push and hold [F-4•DEF] for 1 sec. to select a default value.

uPush [AGC] (MF5) to select slow time constant.

iRotate the main dial to set the desired time constant for ‘AGC SLOW.’

AGC time constant can be set between 0.1 to 8.0 sec. (depends on mode) or turned OFF.

Push and hold [F-4•DEF] for 1 sec. to select a default value.

oSelect another non-FM mode. Repeat steps e to i if desired.

!0Push EXIT/SET to exit the AGC set mode screen.

5-11