[AGC] control AGC VR AGC
FUNCTIONS FOR RECEIVE | 5 |
The AGC (auto gain control) controls receiver gain to produce a constant audio output level even when the received signal strength varies greatly.
The transceiver has 3 preset AGC characteristics (time constant: fast, mid, slow) for
The FM mode AGC time constant is fixed as ‘FAST’
(0.1 sec.) and AGC time constant cannot be
changed.
qSelect any
wPush [AGC] (MF5) several times to select AGC fast,
AGC medium (MID) or AGC slow.
• Push and hold AGC VR for 1 sec. to turn the AGC function OFF.
qSelect any
wPush AGC VR , then rotate [AGC] control to adjust the AGC time constant.
• [AGC VR] indicator above the switch lights green.
• Selectable AGC time constant | (unit: sec.) | ||||
Mode | Default | Selectable AGC time constant | |||
| 0.3 | (FAST) | 0.1, 0.2, 0.3, 0.5, 0.8, 1.2, 1.6, 2.0, | ||
SSB | 2.0 | (MID) | |||
2.5, 3.0, 4.0, 5.0, 6.0 |
| ||||
| 6.0 | (SLOW) |
| ||
|
|
|
|
| |
| 0.1 | (FAST) | 0.1, 0.2, 0.3, 0.5, 0.8, 1.2, 1.6, 2.0, | ||
CW | 0.5 | (MID) | |||
2.5, 3.0, 4.0, 5.0, 6.0 |
| ||||
| 1.2 | (SLOW) |
| ||
|
|
|
| ||
RTTY | 0.1 | (FAST) | 0.1, 0.2, 0.3, 0.5, 0.8, 1.2, 1.6, 2.0, | ||
0.5 | (MID) | ||||
PSK | 2.5, 3.0, 4.0, 5.0, 6.0 |
| |||
|
|
| |||
1.2 | (SLOW) |
| |||
|
|
|
|
| |
| 3.0 | (FAST) | 0.3, 0.5, 0.8, 1.2, 1.6, 2.0, 2.5, 3.0, | ||
|
|
| |||
AM | 5.0 | (MID) | |||
4.0, 5.0, 6.0, 7.0, 8.0 |
| ||||
|
|
|
| ||
| 7.0 | (SLOW) |
| ||
|
|
|
|
| |
FM | 0.1 | (FAST) | Fixed |
| |
|
|
|
|
|
qSelect any
wPush and hold [AGC] (MF5) for 1 sec. to enter AGC set mode.
ePush [AGC] (MF5) several times to select FAST time constant.
rRotate the main dial to set the desired time constant for ‘AGC FAST.’
•AGC time constant can be set between 0.1 to 8.0 sec. (depends on mode) or turned OFF.
•Push and hold
tPush [AGC] (MF5) to select medium time constant. yRotate the main dial to set the desired time constant
for ‘AGC MID.’
•AGC time constant can be set between 0.1 to 8.0 sec. (depends on mode) or turned OFF.
•Push and hold
uPush [AGC] (MF5) to select slow time constant.
iRotate the main dial to set the desired time constant for ‘AGC SLOW.’
•AGC time constant can be set between 0.1 to 8.0 sec. (depends on mode) or turned OFF.
•Push and hold
oSelect another
!0Push EXIT/SET to exit the AGC set mode screen.