CONTROL COMMAND 14
DCommand table

Command

Sub command

Description

 

 

 

00

Send frequency data

 

 

 

01

Same as

Send mode data

 

command 06

 

 

 

 

02

Read band edge frequencies

 

 

 

03

Read operating frequency

 

 

 

04

Read operating mode

 

 

 

05

Set operating frequency

 

 

 

06

00

Select LSB

 

01

Select USB

 

02

Select AM

 

03

Select CW

 

04

Select RTTY

 

05

Select FM

 

07

Select CW-R

 

08

Select RTTY-R

 

12

Select PSK

 

13

Select PSK-R

 

 

 

07

Select VFO mode

 

00

Select VFO-A

 

01

Select VFO-B

 

A0

Equalize VFO-A and VFO-B

 

B0

Exchange VFO-A and VFO-B

 

 

 

08

Select memory mode

 

0001–0101*

Select memory channel

 

 

*P1=0100, P2=0101

 

 

 

09

Memory write

 

 

 

0A

Memory to VFO

 

 

 

0B

Memory clear

 

 

 

0E

00

Scan stop

 

01

Programmed/memory scan start

 

02

Programmed scan start

 

03

F scan start

 

12

Fine programmed scan start

 

13

Fine F scan start

 

22

Memory scan start

 

23

Select memory scan start

 

A1–A7

Set F scan span (A1=±5 kHz;

 

 

A2=±10 kHz; A3=±20 kHz;

 

 

A4=±50 kHz; A5=±100 kHz;

 

 

A6=±500 kHz; A7=±1 MHz)

 

B0

Set as non-select channel

 

B1

Set as select channel

 

 

(1=1; 2=2; 3=3; when no

 

 

data command is specified, the

 

 

previously set number or “1” is

 

 

selected)

 

B2

Set the number for select memory

 

 

scan (0=ALL; 1=1; 2=2; 3=3)

 

D0

Set scan resume OFF

 

D3

Set scan resume ON

 

 

 

0F

00

Turn the split function OFF

 

01

Turn the split function ON

 

 

 

10

00

Select 10 Hz (1 Hz) tuning step

 

01

Select 100 Hz tuning step

 

02

Select 1 kHz tuning step

 

03

Select 5 kHz tuning step

 

04

Select 9 kHz tuning step

 

05

Select 10 kHz tuning step

 

06

Select 12.5 kHz tuning step

 

07

Select 20 kHz tuning step

 

08

Select 25 kHz tuning step

 

 

 

Command

Sub command

Description

 

 

 

11

Select/read attenuator

 

 

(0=OFF; 1=6 dB; 2=12 dB;

 

 

3=18 dB)

12

00 + RX ANT

Select/read ANT1 selection

 

 

(00=RX ANT OFF;

 

 

01=RX ANT ON)

 

01 + RX ANT

Select/read ANT2 selection

 

 

(00=RX ANT OFF;

 

 

01=RX ANT ON)

 

02 + RX ANT

Select/read ANT3 selection

 

 

(00=RX ANT OFF;

 

 

01=RX ANT ON)

 

03 + RX ANT

Select/read ANT4 selection

 

 

(00=RX ANT OFF;

 

 

01=RX ANT ON)

13

00

Announce with voice synthesizer

 

01

(00=all data; 01=frequency and

 

02

S-meter level; 02=receive mode)

 

 

 

14

01 + Level data

[AF] level setting

 

 

(0=max. CCW to 255=max. CW)

 

02 + Level data

[RF] level setting

 

 

(0=max. CCW to 255=11 o’clock)

 

03 + Level data

[SQL] level setting

 

 

(0=11 o’clock to 255=max. CW)

 

05 + Level data

[APF] level setting

 

 

(0=Pitch–550 Hz, 128=Pitch,

 

 

255=Pitch+550 Hz; 10 Hz steps)

 

06 + Level data

[NR] level setting

 

 

(0=min. to 255=max.)

 

07 + Level data

Inside [TWIN PBT] setting or IF

 

 

shift setting (0=max. CCW,

 

 

128=center, 255=max. CW)

 

08 + Level data

Outside [TWIN PBT] setting

 

 

(0=max. CCW, 128=center,

 

 

255=max. CW)

 

09 + Level data

[CW PITCH] setting

 

 

(0=300 Hz, 128=600 Hz,

 

 

255=900 Hz; 5 Hz steps)

 

0A + Level data

[RF POWER] setting (0=max.

 

 

CCW to 255=max. CW)

 

0B + Level data

[MIC] setting (0=max. CCW to

 

 

255=max. CW)

 

0C + Level data

[KEY SPEED] setting (0=max.

 

 

CCW to 255=max. CW)

 

0D + Level data

[NOTCH] setting

 

 

(0=low freq. to 255=high freq.)

 

0E + Level data

[COMP] setting

 

 

(0=max. CCW to 255=max. CW)

 

0F + Level data

[DELAY] setting

 

 

(0=max. CCW to 255=max. CW)

 

11 + Level data

[AGC] control setting

 

 

(0=max. CCW to 255=max. CW)

 

12 + Level data

[NB] control setting

 

 

(0=max. CCW to 255=max. CW)

 

13 + Level data

[DIGI-SEL] setting

 

 

(0=max. CCW to 255=max. CW)

 

14 + Level data

[DRIVE] setting

 

 

(0=max. CCW to 255=max. CW)

 

15 + Level data

[MONI GAIN] setting (0=max.

 

 

CCW to 255=max. CW)

 

16 + Level data

[VOX GAIN] setting (0=max.

 

 

CCW to 255=max. CW)

 

17 + Level data

[ANTI VOX] setting

 

 

(0=max. CCW to 255=max. CW)

 

 

 

14-3