Warning

The following table gives a summary of system log warning messages which may be received from the scanner alert monitoring service.

The messages shown here are sent to the e-mail address specified in "3.6.9 Setting the Destination for Alert Notifications" (page 84).

Code

Message

Action

 

 

 

82000004

LCD backlight rated lifetime reached.

LCD backlight has reached 50,000

 

Replace as convenient.

hours of operation, its

 

 

recommended rated lifetime. The

 

 

backlight should be replaced when

 

 

convenient.

 

 

 

82000005

Pad assembly needs replacement soon.

Obtain a replacement pad

 

 

assembly soon.

 

 

The pad assembly should be

 

 

replaced after every 50,000

 

 

scanned sheets or once a year.

 

 

 

82000006

Pad assembly needs replacement now.

Pad assembly has passed its rated

 

 

lifetime (50,000 scanned sheets or

 

 

one a year) and needs to be

 

 

replaced.

 

 

 

82000007

Pick roller needs replacement soon.

Obtain a replacement pick roller.

 

 

The pick roller should be replaced

 

 

after every 100,000 scanned sheets

 

 

or once a year.

 

 

 

82000008

Pick roller needs replacement now.

Pick roller has passed its rated

 

 

lifetime (100,000 scanned sheets

 

 

or one a year) and needs to be

 

 

replaced.

 

 

 