Hz Tol.

: Input the tolerance for Hz-directions.

 

This defines the limit for the

 

difference between the actual direction

 

and the direction observed within the

 

first half set. A change in the horizon-

 

tal circle orientation is always

 

accounted for, after observing the first

 

target within a new set. If the

 

tolerance is exceeded, a warning is

 

given.

V Angle Tol

: Input the tolerance for vertical

 

directions. This defines the limit for

 

the difference in the vertical directions

 

between the actual observations and

 

the directions observed within the first

 

half set. If the tolerance is exceeded, a

 

warning is given.

Log File

: ON, records measurements in a Log-

 

File.The format is described on page

 

146.

Log FlName

: Enter the Log File Name.

Displays date and version.

Set default values. Default values are displayed in dialog "CONFIGURATION" (page 143).

Exit the program

Store the current configuration and proceed to the dialog "SETS MENU".