Deflct.Tol. : Permissible deviation of the tangent directions for adjacent elements. A message appears if this value is exceeded. The input is always in milligon.

ChaingeTol. : Permissible deviation of the (chord) length of an element and of the distance calculated from the end-point coordinates, expressed in the length units set. A message appears if this value is exceeded.

3D Stake : ON for setting out positions and heights. The height can be set out only if the V-alignment has been defined. OFF for setting out only positions. Neither a V-alignment nor a typical cross-section can be set out.

Log File : Set to ON, the program will record measurement data in a log file in the format described on page 190.

Log FlName : Enter the log file name.

Displays date and version of the program.

Sets standard values . The values are displayed in dialog on page 188.

RO

Accepts and stores parameters displayed. Continues to display "SELECT ALN FILES".

© Leica

TPS-System 1000 Programs-2.3.1en

189