Dual-face Measurement In the dual-face mode, the program will prompt for measurements in both faces. When both measurements are taken, the program will check the difference between the two. If the difference in angle is within 27' (0.5 gon) and the difference of two measured distances is within 0.5 m (1.64 ft), the observations will be averaged. These tolerances are used to avoid errors in target identification. If exceeded an error message will be displayed.

170

TPS-System 1000 Programs-2.3.1en

© Leica

Page 171
Image 171
Leica 1000Z01 user manual 170