The data block

11....+0STATION 71....+GEOM_ELE 72....+RAD/PARA 73....+TEMPLATE

81..10+00000000 82..10+00000000

WI 11 STATION: Chainage at the start of the element. 8-digit number.

WI 71 GEOM_ELE: Geometrical element according to table page 190 (STRAIGHT, 000CURVE, 00SPIRIN, 0SPIROUT, 00000EOP).

WI 72 RAD/PARA: Arc radius or A-parameter for the spirals. 8-digit number.

If WI 71 = STRAIGHT / 00000EOP, then WI 72 = 00000NON.

Sign:

+, for curves to the right (centre of circle to the right of the alignment),

-, for curves to the left (centre of circle to the left of the alignment).

WI 73 TEMPLATE: Name/number of the cross- sectional profile for the geometrical element defined in WI 71. 8 alphanumeric characters. The following combinations are reserved and are not to be used: 00000NON and

LASTTMPL.

WI 81 E-coordinate of the main point (starting point, start of curve, end point according to table page 190). 8-digit number.

WI 82 N-coordinate of the main point (starting point, start of curve, end point according to table page 190). 8-digit number.

194

TPS-System 1000 Programs-2.3.1en

© Leica