Set all values to default. Default values are shown in dialog on page 160.

Select (NO/YES, alpha-numeric/numeric input, ON/

OFF).

Confirm displayed parameter and continues with the "TRAVERSE MENU".

Dual-face Measurement In the dual-face mode, the program will prompt for measurements in both faces. When both measurements are taken, the program will check the difference between the two. If the difference in angle is within 27' (0.5 gon) and the difference of two measured distances is within 0.5 m (1.64 ft), the observations will be averaged. These tolerances are used to avoid errors in target identification. If exceeded an error message will be displayed.

Multiple Measurement

The measurement to a point can be repeated as often as

 

desired to achieve a higher accuracy or reliability. The

 

mean value of the measurements and the respective

 

standard deviation is displayed.