Checking files

The files selected are inspected for formal input errors

 

and for geometrical deviations.

 

The job identification for the three input files is

 

inspected, as are possible errors in the data format e.g.

 

missing or incorrect word index (WI). Errors are

 

indicated by appropriate messages. The inspection can

 

be continued or interrupted. If serious formal errors

 

are found, the inspection is aborted.

 

Geometrical deviations include the tangent directions

 

of adjacent elements and the chord lengths of elements.

 

Deviations which exceed the permitted tolerance are

 

displayed. The inspection of the files can be continued

 

or interrupted.

ROADL\ CHECKING FILES

14:03

ALN: Deflection tolerance exceeded at chainage 89°18'00". Difference in direction is 0°00'27". Override?

MC

NO YES

F1

F2

F3

F4

F5

 

 

 

 

 

F6

After inspection, the program returns to Dialog 2. The input values can be corrected, either on a PC using the program "ROADDATA.EXE" or on the TPS1000 using the programm "FILE EDITOR".