Results of sets of angles are recorded in the activ file for measurements. (For details see dialog "FORMATS AND MORE INFORMATION" )

Show the results of individual measurements on the screen. ( For details see dialog "MORE INFORMATI- ON")

Exit the program

• Formats and Data Recording

The following format is used to record results in the activ file for measurements.

Number of measurements and accuracies.

WI 41 Code "HZ-RESLT" or "V0-RESLT"

WI 42 Number of targets.

WI 43 Number of observed sets.

WI 44 Standard deviation of a horizontal or vertical direction.

WI 45 Standard deviation of a horizontal or a vertical direction averaged from all sets.

HZ-RESLT:(Number of observations and accuracies)

Code

Number of

Number of

mR

mM

 

targets

sets

 

 

 

=4

=3

= 52"

= 37"

 

 

 

 

 

410039+HZ-RESLT

42 +00000004....

43 +00000003....

44 +00000520....

45 +00000370....

 

 

 

 

 

WI 41

WI 42

WI 43

WI 44

WI 45

 

 

 

 

 

136

TPS-System 1000 Programs-2.3.1en

© Leica

Page 137
Image 137
Leica 1000Z01 user manual Formats and Data Recording, Number of measurements and accuracies