Leica 1000Z01 user manual Orient Standard deviation of the Orientation

Models: 1000Z01

1 347
Download 347 pages 59.8 Kb
Page 85
Image 85

σOrient : Standard deviation of the Orientation

Calc Scale

: YES scale factor is calculated,

 

NO scale factor is not calculated

Scale

: The scale factor of the free station

 

calculation.

 

Note that the scale is not shown if

 

set to NO.

Set orientation and station coordinates on the instrument. Note that this key will end the program.

Record the following results on the active recording device:

WI 11

Station Point Number

WI 25

Orientation correction

WI 84

Station Easting

WI 85

Station Northing

WI 86

Station Elevation

WI 87

Last reflector height used

WI 88

Instrument Height

Sketch of the station and the reference points used.

Show the results of individual measurements on the screen (see dialog "More Information").

Measure more points. The program will recall the "TARGET POINT" dialog.

Select between the "Robust" method and the "Variati- on" method

Exit the program.