Leica 1000Z01 user manual Data block, 72 = 00000NON

Models: 1000Z01

1 347
Download 347 pages 59.8 Kb
Page 200
Image 200

The Data block

11....+0STATION 71....+GEOM_ELE 72....+RAD/PARA 83..10+00HEIGHT

WI 11 STATION: Chainage (from the Hz- alignment) at the start of the element. 8-digit number.

WI 71 GEOM_ELE: Geometrical element according to table page 195 (STRAIGHT, 000CURVE, PARABOLA, 00000EOP).

WI 72 RAD/PARA: Arc radius or parabola

parameter. 8-digit number.

If WI 71 = STRAIGHT / 00000EOP, then WI

72= 00000NON.

Sign: "+" = dip, "-" = crest

WI 83 HEIGHT: Height H of the main point (starting point, start of curve, end point, in accordance with table page 195). 8-digit number.

Also:

The header is always at the beginning of a data file.

The V-alignment file must be composed of at least two parts (starting- and finishing point).

The units and decimal places used in the WIs 11 and 72 are in accordance with the definition in WI 83.

The chainage is given by the sum of the horizontal element lengths.

Geometrical elements can be combined freely.

• There is no limitation on the size of the V-alignment file. As a result, as many data blocks as required can be entered if a file is created on the PC using the DOS program "ROADDATA.EXE". If a file is created/edited using the program "FILE EDITOR" on the TPS1000 there is a limitation of 200 data blocks.

RO

Check your data for errors (typing errors, signs etc.) before you load it into the memory card.

© Leica

TPS-System 1000 Programs-2.3.1en