Installing the optional ServeRAID-MR10i SAS/SATA controller
The optional
Important: To ensure that any of your ServeRAID 10i, 10is, or 10M adapters function properly on
Attention: Some cluster solutions require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the code.
To install the
1.Read the safety information (see “Safety” on page vii and “Installation guidelines” on page 37).
2.Turn off the server and peripheral devices, and disconnect the power cords and all external cables. Remove the side cover (see “Removing the side cover” on page 43).
Attention: To avoid breaking the retaining clips or damaging the
3.Remove the side cover (see “Removing the side cover” on page 43).
4.Carefully position the server on its side so that it is lying flat and facing up. Note: Do not allow the server to fall over.
5.Remove the screw that secures the
Note:
6.Open the retaining clips on each end of the
7.Touch the
8.If the battery pack (battery carrier and battery) did not come installed on the ServeRAID adapter, install the battery pack.
a.Align the battery carrier pins and the connector for the battery carrier with the pin holes and connector on the ServeRAID adapter; then, lower the battery carrier onto the ServeRAID adapter.
112ThinkServer TD200 Types 3724, 3808, 3809, 3815, 3817, 3824, 3826, 3836: Installation and User Guide