vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
vSee the Hardware Maintenance Manual to determine which components are customer replaceable units (CRUs) and which components are field replaceable units (FRUs).
vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.
Error code | Description | Action | |
|
|
|
|
005100A | No usable memory detected. | 1. | Make sure that the server contains DIMMs. |
|
| ||
|
| 2. | Reseat the DIMMs. |
|
| 3. | Install DIMMs in the correct sequence (see |
|
|
| “Installing a memory module” on page 89). |
|
| 4. | Clear CMOS memory to |
|
|
| connectors (see |
|
|
| jumpers” on page 31). |
|
|
|
|
0058001 | PFA threshold exceeded | 1. | Update the server firmware to the latest level (see |
|
| ||
|
|
| “Updating the firmware” on page 151). |
|
| 2. | Reseat the DIMMs and run the memory test (see |
|
|
| the Hardware Maintenance Manual). |
|
| 3. | Replace the failing DIMM, which is indicated by a |
|
|
| lit LED on the system board. |
|
|
|
|
0058007 | DIMM population is unsupported. | 1. | Reseat the DIMMs, and then restart the server. |
|
| ||
|
| 2. | Remove the |
|
|
| that are identified and replace it with an identical |
|
|
| pair of known good DIMMs, then restart the |
|
|
| server. |
|
| 3. | Return the removed DIMMs, one pair at a time, to |
|
|
| their original connectors, restarting the server after |
|
|
| each pair, until a pair fails. Replace the DIMMs in |
|
|
| the failed pair with identical known good DIMMs, |
|
|
| restarting the server after each DIMM is installed. |
|
|
| Replace the failed DIMM. Repeat this step until |
|
|
| you have tested all removed DIMMs. |
|
| 4. | (Trained service technician only) Replace the |
|
|
| system board. |
|
|
|
|
0058008 | DIMM failed memory test. | 1. | Reseat the DIMMs, and then restart the server. |
|
| ||
|
| 2. | Replace the following components one at a time, |
|
|
| in the order shown, then restart the server after |
|
|
| each: |
|
|
| a. DIMM |
|
|
| b. (Trained service technician only) System |
|
|
| board |
|
|
|
|
00580A1 | Invalid DIMM population for mirroring mode | 1. | If a fault LED is lit, resolve the failure. |
|
| ||
|
| 2. | Install the DIMMs in the correct sequence (see |
|
|
| “Installing a memory module” on page 89). |
|
|
| |
00580A4 | Memory population changed. | Information only. Memory has been added, moved, or | |
|
| changed. | |
|
|
| |
00580A5 | Mirror failover complete | Information only. Memory redundancy has been lost. | |
|
| Check the event log for uncorrected DIMM failure | |
|
| events. | |
|
|
|
|