vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee the Hardware Maintenance Manual to determine which components are customer replaceable units (CRUs) and which components are field replaceable units (FRUs).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Error code

Description

Action

 

 

 

 

0011004

Microprocessor failed BIST.

1.

Update the server firmware to the latest level (see

 

 

 

 

 

“Updating the firmware” on page 151).

 

 

2.

(Trained service technician only) Reseat

 

 

 

microprocessor 2.

 

 

3.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a. (Trained service technician only)

 

 

 

Microprocessor

 

 

 

b. (Trained service technician only) System

 

 

 

board

 

 

 

 

001100A

Microcode updated failed.

1.

Update the server firmware to the latest level (see

 

 

 

 

 

“Updating the firmware” on page 151).

 

 

2.

(Trained service technician only) Replace the

 

 

 

microprocessor.

 

 

 

 

0050001

DIMM disabled.

1.

If the server fails the POST memory test, reseat

 

 

 

 

 

the DIMMs.

 

 

2.

Remove and replace any DIMM for which the

 

 

 

associated error LED is lit (see “Removing a

 

 

 

memory module” on page 86 and “Installing a

 

 

 

memory module” on page 89).

 

 

3.

Run the Setup Utility to enable all the DIMMs.

 

 

4.

Run the DSA Preboot memory test (see 8).

 

 

 

 

0051003

Uncorrectable DIMM error

1.

If the server failed the POST memory test, reseat

 

 

 

 

 

the DIMMs.

 

 

2.

Remove and replace any DIMM for which the

 

 

 

associated error LED is lit (see “Removing a

 

 

 

memory module” on page 86 and “Installing a

 

 

 

memory module” on page 89).

 

 

3.

Run the Setup Utility to enable all the DIMMs.

 

 

4.

Run the DSA Preboot memory test (see8).

 

 

 

0051006

DIMM mismatch detected

Make sure that the DIMMs match and are installed in

 

 

the correct sequence (see “Installing a memory

 

 

module” on page 89).

 

 

 

 

0051009

No memory detected.

1.

Make sure that the server contains DIMMs.

 

 

 

 

2.

Reseat the DIMMs.

 

 

3.

Install DIMMs in the correct sequence (see

 

 

 

“Installing a memory module” on page 89).

 

 

 

 