1 SATA optical drive power cable 2 USB signal cable connector 3 USB signal cable

4 SATA optical drive power cable (SATA-to-traditional power converter cable also included but not pictured)

5 SATA optical drive signal cable

8.Reinstall the fan cage assembly. Align the fan cage assembly over the fan cage assembly slot and with the connector on the system board. Lower the fan cage assembly into the chassis and press down firmly until the fan cage assembly is seated firmly in place.

Note: Make sure that all wires and cables inside the server are routed correctly before installing the fan cage assembly. Wiring that is not properly routed could be damaged or might prevent the fan cage assembly from seating properly in the server.

9.Install the air baffle (see “Installing the air baffle” on page 132).

10.Rotate the power-supply cage assembly back into the server. Press the power-supply cage release tab and rotate the power-supply cage assembly into the chassis.

11.Close the bezel.

12.Install the side cover (see “Installing the side cover” on page 134).

13.Lock the side cover.

14.Reconnect the external cables and power cords; then, turn on the attached devices and turn on the server.

If you have other options to install or remove, do so now; otherwise go to “Completing the installation” on page 130.

Chapter 5. Installing optional devices and replacing customer replaceable units 69

Page 87