vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
vSee the Hardware Maintenance Manual to determine which components are customer replaceable units (CRUs) and which components are field replaceable units (FRUs).
vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.
Error code | Description | Action | |
|
|
|
|
0068002 | CMOS battery cleared. | 1. | Reseat the battery. |
|
| ||
|
| 2. | Clear the CMOS memory. |
|
| 3. | Replace the following components one at a time, |
|
|
| in the following order, restarting the server after |
|
|
| each one: |
|
|
| a. Battery |
|
|
| b. (Trained service technician only) System |
|
|
| board. |
|
|
|
|
2011001 |
| 1. | Reseat all affected adapters. |
|
| ||
|
| 2. | Update the PCI adapter firmware. |
|
| 3. | Remove the adapter. |
|
| 4. | Replace the following components one at a time, |
|
|
| in the order shown, restarting the server each |
|
|
| time: |
|
|
| a. Adapter |
|
|
| b. (Trained service technician only) System |
|
|
| board |
|
|
|
|
2018001 | PCI Express uncorrected or uncorrected error | 1. | Reseat all affected adapters. |
|
| 2. | Update the PCI adapter firmware. |
|
| 3. | Remove the adapter. |
|
| 4. | Replace the following components one at a time, |
|
|
| in the order shown, restarting the server each |
|
|
| time: |
|
|
| a. Adapter |
|
|
| b. (Trained service technician only) System |
|
|
| board |
|
|
|
|
182ThinkServer TD200 Types 3724, 3808, 3809, 3815, 3817, 3824, 3826, 3836: Installation and User Guide