for x4 and x8 adapters. These same rules apply to the other PCI slots also. Check the information that comes with your adapter for compatibility information.
–Slots on the system board:
-Slot 1, PCI Express Gen 2 x8 (x8)
-Slot 2, PCI Express Gen 2 x16 (x8)
-Slot 3, PCI Express Gen 2 x8 (x4)
-Slot 4, PCI Express Gen 2 x8 (x4)
-Slot 5, PCI Express Gen 2 x8 (x8)
-Slot 6, PCI
–If you install the
-One additional PCI Express Gen 1 x8 (x4) slot is available
–If you install the
v You can install
vThe
vYou can install the
vThe
To ensure that any of your ServeRAID 10i, 10is, or 10M adapters function properly on
Attention: Some cluster solutions require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the code.
vThe server scans PCI Express slot 1 and PCI Express slots 2 and 3 to assign system resources. Then, the server starts the devices in the following order, if you have not changed the default startup sequence: PCI Express slot 1, PCI Express slot 2, PCI slot 6, and PCI Express slot 3.
vFor a list of supported options for the server, see http://www.lenovo.com/thinkserver.
To install an adapter, do the following:
Note: The instructions in this section apply to any PCI adapter (for example, video graphics adapters or network adapters).
1.Read the safety information (see “Safety” on page vii and “Installation guidelines” on page 37).
2.Turn off the server and peripheral devices and disconnect all external cables and power cords; then, remove the side cover. See “Removing the side cover” on page 43.
3.Carefully position the server on its side so that it is lying flat and facing up.
Chapter 5. Installing optional devices and replacing customer replaceable units 97