1 ServeRAID-MR10i controller 2 PCI slot 1

10.Press the ServeRAID-MR10i adapter firmly into the connector on the system board.

11.Rotate the power-supply cage assembly out of the chassis. Lift up the power-supply cage handle and pull the power-supply cage assembly all the way up until the retainer latch locks the cage in place on the chassis.

1 Power supply

2 Power-supply handle

12.Remove the air baffle (see “Removing the air baffle” on page 44).

13.Remove the front fan cage assembly (see “Removing the fan cage assembly” on page 46).

14.Connect the configuration signal cable. See “Power and signal cables for internal drives” on page 78 for information about cabling the power and signal cables.

15.Complete the cabling of the ServeRAID-MR10i adapter. See “Power and signal cables for internal drives” on page 78 for additional information about cabling the power and signal cables.

v For the eight drive-bay, 2.5-inch server model, connect one end of the signal cable to the drive backplane for drive bays 0 through 3 and route the other end through the plastic slot on the bottom of the chassis underneath the front fan cage; then, connect it to the ServeRAID-MR10i SAS/SATA controller as shown in the following illustrations:

114ThinkServer TD200 Types 3724, 3808, 3809, 3815, 3817, 3824, 3826, 3836: Installation and User Guide