vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
vSee the Hardware Maintenance Manual to determine which components are customer replaceable units (CRUs) and which components are field replaceable units (FRUs).
vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.
Error code | Description | Action | |
|
|
|
|
3048006 | Booted secondary (backup) UEFI image | 1. | Run the Setup Utility, select Load Default |
| because of ABR | ||
|
| Settings, and save the settings to recover the | |
|
|
| |
|
|
| primary UEFI settings. |
|
| 2. | Turn off the server and remove it from the power |
|
|
| source. |
|
| 3. | Reconnect the server to the power source, then |
|
|
| turn on the server. |
|
|
|
|
3058000A | RTC date/time is incorrect | 1. | Adjust the date and time settings in the Setup |
|
| ||
|
|
| Utility, and then restart the server. |
|
| 2. | Reseat the battery. |
|
| 3. | Replace the following components one at a time, |
|
|
| in the order shown, restarting the server each |
|
|
| time: |
|
|
| a. Battery |
|
|
| b. (Trained service technician only) System |
|
|
| board |
|
|
|
|
3058001 | System configuration invalid | 1. | Run the Setup Utility, and select Save Settings. |
|
| ||
|
| 2. | Run the Setup Utility, select Load Default |
|
|
| Settings, and save the settings. |
|
| 3. | Reseat the following components one at a time in |
|
|
| the order shown, restarting the server each time: |
|
|
| a. Battery |
|
|
| b. Failing device (if the device is a FRU, then it |
|
|
| must be reseated by a trained service |
|
|
| technician only) |
|
| 4. | Replace the following components one at a time, |
|
|
| in the order shown, restarting the server each |
|
|
| time: |
|
|
| a. Battery |
|
|
| b. Failing device (if the device is a FRU, then it |
|
|
| must be replaced by a trained service |
|
|
| technician only) |
|
|
| c. (Trained service technician only) System board |
|
|
|
|
3058004 | Three boot failure | 1. | Undo any recent system changes, such as new |
|
| ||
|
|
| settings or newly installed devices. |
|
| 2. | Make sure that the server is attached to a reliable |
|
|
| power source. |
|
| 3. | Remove all hardware that is not listed on the |
|
|
| Lenovo Web site at |
|
|
| http://www.lenovo.com/thinkserver. |
|
| 4. | Make sure that the operating system is not |
|
|
| corrupted. |
|
| 5. | Run the Setup Utility, save the configuration, and |
|
|
| then restart the server. |
|
|
|
|
184ThinkServer TD200 Types 3724, 3808, 3809, 3815, 3817, 3824, 3826, 3836: Installation and User Guide