vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee the Hardware Maintenance Manual to determine which components are customer replaceable units (CRUs) and which components are field replaceable units (FRUs).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Error code

Description

Action

 

 

 

 

3048006

Booted secondary (backup) UEFI image

1.

Run the Setup Utility, select Load Default

 

because of ABR

 

 

Settings, and save the settings to recover the

 

 

 

 

 

 

primary UEFI settings.

 

 

2.

Turn off the server and remove it from the power

 

 

 

source.

 

 

3.

Reconnect the server to the power source, then

 

 

 

turn on the server.

 

 

 

 

3058000A

RTC date/time is incorrect

1.

Adjust the date and time settings in the Setup

 

 

 

 

 

Utility, and then restart the server.

 

 

2.

Reseat the battery.

 

 

3.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a. Battery

 

 

 

b. (Trained service technician only) System

 

 

 

board

 

 

 

 

3058001

System configuration invalid

1.

Run the Setup Utility, and select Save Settings.

 

 

 

 

2.

Run the Setup Utility, select Load Default

 

 

 

Settings, and save the settings.

 

 

3.

Reseat the following components one at a time in

 

 

 

the order shown, restarting the server each time:

 

 

 

a. Battery

 

 

 

b. Failing device (if the device is a FRU, then it

 

 

 

must be reseated by a trained service

 

 

 

technician only)

 

 

4.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a. Battery

 

 

 

b. Failing device (if the device is a FRU, then it

 

 

 

must be replaced by a trained service

 

 

 

technician only)

 

 

 

c. (Trained service technician only) System board

 

 

 

 

3058004

Three boot failure

1.

Undo any recent system changes, such as new

 

 

 

 

 

settings or newly installed devices.

 

 

2.

Make sure that the server is attached to a reliable

 

 

 

power source.

 

 

3.

Remove all hardware that is not listed on the

 

 

 

Lenovo Web site at

 

 

 

http://www.lenovo.com/thinkserver.

 

 

4.

Make sure that the operating system is not

 

 

 

corrupted.

 

 

5.

Run the Setup Utility, save the configuration, and

 

 

 

then restart the server.

 

 

 

 