1 Power supply support bracket 2 Power supply release tab
5.Install the side cover (see “Installing the side cover” on page 134).
6.Lock the side cover.
7.Reconnect the external cables and power cords; then, turn on the attached devices and turn on the server.
Removing a hot-swap fan
Attention:
vReplace a
vTo ensure proper cooling and airflow, do not operate the server for more than 2 minutes with the side cover removed.
To replace a
1.Read the safety information (see “Safety” on page vii and “Installation guidelines” on page 37).
Attention: Static electricity that is released to internal server components when the server is powered on might cause the server to halt, which could result in the loss of data. To avoid this potential problem, always use an
2.Unlock and remove the side cover (see “Removing the side cover” on page 43).
3.With your finger, slide the orange release tab in the direction indicated by the arrow on top of the fan to unlock the fan handle. Grasp the fan handle and pull the fan 1 out of the fan cage assembly.
84ThinkServer TD200 Types 3724, 3808, 3809, 3815, 3817, 3824, 3826, 3836: Installation and User Guide