3.Press down on the fan until it locks into place; then, close the fan handle to the locking position.

4.Install the side cover (see “Installing the side cover” on page 134).

5.Lock the side cover.

Removing a memory module

To remove a DIMM, do the following:

1.Read the safety information (see “Safety” on page vii and “Installation guidelines” on page 37).

2.Turn off the server and all attached devices; then, disconnect all power cords and external cables.

3.Carefully position the server on its side so that it is facing up. Note: Do not allow the server to fall over.

4.Unlock and remove the side cover (see “Removing the side cover” on page 43).

5.Rotate the power-supply cage assembly out of the chassis. Lift up the power-supply cage handle and pull the power-supply cage assembly all the way up until the retainer latch locks the cage in place on the chassis.

86ThinkServer TD200 Types 3724, 3808, 3809, 3815, 3817, 3824, 3826, 3836: Installation and User Guide

Page 104
Image 104
Lenovo 3836, 3809, 3826, 3724, 3824, 3808, 3815, 3817 manual Removing a memory module