Lenovo 3808, 3836, 3809, 3826 Server power features, Turning on the server, Turning off the server

Models: 3836 3826 3824 3817 3809 3808 3815 3724

1 228
Download 228 pages 30.54 Kb
Page 53
Image 53

Server power features

When the server is connected to an ac power source but is not turned on, the operating system does not run, and all core logic except for the service processor (the Integrated Management Module) is shut down; however, the server can respond to requests to the service processor, such as a remote request to turn on the server. The power-on LED flashes to indicate that the server is connected to ac power but is not turned on.

Turning on the server

Approximately 5 seconds after the server is connected to ac power, one or more fans might start running to provide cooling while the server is connected to power and the power-on button LED will blink quickly. Approximately 1 to 3 minutes after the server is connected to ac power, the power-control button becomes active (the power-on LED will blink slowly). You can turn on the server by pressing the power-control button.

The server can also be turned on in any of the following ways:

vIf a power failure occurs while the server is turned on, the server will restart automatically when power is restored.

Note: When 4 GB or more of memory (physical or logical) is installed, some memory is reserved for various system resources and is unavailable to the operating system. The amount of memory that is reserved for system resources depends on the operating system, the configuration of the server, and the configured peripheral component interconnect (PCI) options.

Turning off the server

When you turn off the server and leave it connected to ac power, the server can respond to requests to the service processor, such as a remote request to turn on the server. While the server remains connected to ac power, one or more fans might continue to run. To remove all power from the server, you must disconnect it from the power source.

Some operating systems require an orderly shutdown before you turn off the server. See your operating-system documentation for information about shutting down the operating system.

Statement 5:

CAUTION:

The power control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device. The device also might have more than one power cord. To remove all electrical current from the device, ensure that all power cords are disconnected from the power source.

Chapter 4. Server controls, LEDs, and power 35

Page 53
Image 53
Lenovo 3808, 3836, 3809, 3826, 3724, 3824, 3815, 3817 manual Server power features, Turning on the server, Turning off the server