vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
vSee the Hardware Maintenance Manual to determine which components are customer replaceable units (CRUs) and which components are field replaceable units (FRUs).
vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.
Lit EasyLED |
|
|
|
diagnostics LED with |
|
|
|
the |
|
|
|
information LED also |
|
|
|
lit | Description | Action |
|
|
|
|
|
VRM | A VRM has failed. | 1. Check the | |
|
| ||
|
| reason for the lit LED (for a VRM). | |
|
| 2. Determine whether the CNFG LED is also lit. If the | |
|
| CNFG LED is lit, the memory configuration is | |
|
| invalid. Reseat the VRM. | |
|
| 3. If the CNFG LED is not lit, reseat the following | |
|
| components: | |
|
| a. | Failing VRM |
|
| b. (Trained service technician only) | |
|
|
| Microprocessor associated with the VRM |
|
| 4. Replace the following components one at a time, | |
|
| in the order shown, restarting the server each time: | |
|
| a. | Failing VRM |
|
| b. (Trained service technician only) | |
|
|
| Microprocessor associated with the VRM |
|
| c. (Trained service technician only) System board | |
|
|
|
|
Microprocessor (CPU) | A microprocessor has failed, or an | 1. Check the | |
| invalid microprocessor configuration | ||
| reason for the lit LED. | ||
| is installed. | ||
| 2. Determine whether the CNFG LED is also lit. If the | ||
| Note: (Trained service technician | ||
| CNFG LED is not lit, a microprocessor has failed. | ||
| only) Make sure that the | ||
| a. | Make sure that the failing microprocessor, | |
| microprocessors are installed in the | ||
| correct sequence. |
| which is indicated by the CPU1 or CPU2 error |
|
|
| LED on the system board, is installed correctly. |
|
| b. Replace the following components one at a | |
|
|
| time, in the order shown, restarting the server |
|
|
| each time: |
|
|
| 1) (Trained service technician only) Failing |
|
|
| microprocessor |
|
|
| 2) (Trained service technician only) System |
|
|
| board |
|
| c. If the CNFG LED is lit and the CPU mismatch | |
|
|
| LED on the system board is also lit, an invalid |
|
|
| microprocessor configuration is installed: |
|
|
| 1) Make sure that the microprocessors are |
|
|
| compatible with each other. They must |
|
|
| match in speed and cache size. Use the |
|
|
| Setup Utility to compare the microprocessor |
|
|
| information. |
|
|
| 2) (Trained service technician only) Replace |
|
|
| the incompatible microprocessor. |
|
|
|
|