Power problems
vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
vSee the Hardware Maintenance Manual to determine which components are customer replaceable units (CRUs) and which components are field replaceable units (FRUs).
vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.
Symptom | Action | |
The | 1. Make sure that the | |
not work (the server does not | ||
correctly: | ||
start). | ||
a. Disconnect the server power cords. | ||
Note: The | ||
b. Reconnect the power cords. | ||
will not function until 1 to 3 | ||
minutes after the server has | c. Press the | |
been connected to ac power. |
2.Make sure that:
v The power cords are correctly connected to the server and to a working electrical outlet.
vThe power LEDs (ac, dc) are lit correctly.
vThe server
vThe server contains the correct type of DIMMs.
vThe DIMMs are correctly seated.
vA POST beep code did not sound, indicating a memory initialization error.
vThe LEDs on the power supply do not indicate a problem.
vThe microprocessor is correctly installed.
3.Reseat the following components:
|
| a. DIMMs | |
|
| b. | |
| 4. | Replace the following components one at a time, in the order shown, restarting | |
|
| the server each time: | |
|
| a. DIMMs | |
|
| b. (Trained service technician only) Power supply | |
| 5. | If you just installed an optional device, remove it, and restart the server. If the | |
|
| server now starts, you might have installed more devices than the power supply | |
|
| supports. | |
| 6. | See “Solving undetermined problems” on page 173. | |
|
|
|
|
The server does not turn off. | 1. | Determine whether you are using an Advanced Configuration and Power | |
| |||
|
| Interface (ACPI) or a | |
|
| operating system, do the following: | |
|
| a. | Press Ctrl+Alt+Delete. |
|
| b. Turn off the server by holding the | |
|
| c. | Restart the server. |
|
| d. If the server fails POST and the | |
|
|
| disconnect the ac power cord for 20 seconds; then, reconnect the ac power |
|
|
| cord and restart the server. |
| 2. | (Trained service technician only) If the problem remains or if you are using an | |
|
|