Configuring Your Server 4-39

Manual Rebuild

Replace hard disk drive

Run LSI Logic Software RAID Setup Utility

Execute rebuilding

Exit LSI Logic Software RAID Setup Utility

1.Replace a hard disk drive and turn on the server.

2.Run LSI Logic Software RAID Setup Utility.

3.Select "Rebuild" from the TOP menu.

The "Rebuild – PHYSICAL DRIVES SELECTION MENU" screen appears.

4.Move the cursor onto the hard disk drive displaying "FAIL," and then press Space to select it.

Multiple hard disk drives can be selected (simultaneous rebuilding.)

5.The "FAIL" indication for the hard disk drive selected starts blinking.

6.When hard disk drive has been selected, press F10 to start rebuilding.

7.When confirmation screen for execution appears. Select "Yes". The rebuild process starts.

When the progress bar in the "Rebuild Physical Drives in Progress" screen indicates 100%, rebuilding is completed.

8.Press Esc to return to the TOP menu and exit LSI Logic Software RAID Setup Utility.