Upgrading Your Server 9-31

5.Make the component side of the board face the bottom of the server, put the rear panel of the board on the frame spring securely, and push the board fully so that the board connection port is certainly connected to the slot.

For a long-sized board, align the board with the groove of the guide rail on the front of the server and then connect the board to the slot.

IMPORTANT: If the board cannot be installed well, remove the board once and then install it again. Note that adding an excess force to the board may cause it to be damaged.

PCI guide rail

Grooves for guide rail

Frame spring portion

<Long-sized board>

6.Assemble the server.

7.Turn on the power of the server. Make sure that no error message appears in the POST.

If an error message appears, write down the message and contact your service representative for the maintenance.

8.Start the BIOS Setup Utility to set the "Reset Configuration Data" in the "Advanced" menu to "Yes."

This is required to update the hardware configuration information. See Chapter 4 for details.