Troubleshooting 8-9

Error

Error message

Recommended Action

code

 

 

02D1

System Memory exceeds the CPU's caching

Contact your service representative.

 

limit.

 

02F4

EISA CMOS not write able.

 

02F5

DMA Test Failed.

 

02F6

Software NMI Failed.

 

02F7

Fail-safe Timer NMI Failed.

 

0B22

CPUs are installed out of order.

Request the maintenance to replace the CPU.

0B28

Unsupported CPU detected on CPU Slot 1.

Make sure that the server supports the CPU. If

0B29

Unsupported CPU detected on CPU Slot 2.

you are not sure, contact your service

 

 

representative to request the maintenance.

0B30

Fan 1 Alarm occurred.

Contact your service representative to replace

0B31

Fan 2 Alarm occurred.

the fan.

0B32

Fan 3 Alarm occurred.

 

0B5F

Forced to use Processor with error

Because an error is detected in every CPU,

 

 

the system is forcibly started. Contact your

 

 

service representative.

0B60

DIMM group #1 has been disabled

Contact your service representative.

0B61

DIMM group #2 has been disabled

 

0B62

DIMM group #3 has been disabled

 

0B63

DIMM group #4 has been disabled

 

0B64

DIMM group #5 has been disabled

 

0B65

DIMM group #6 has been disabled

 

0B70

The error occurred during temperature

Contact your service representative.

 

sensor reading.

 

0B71

System Temperature out of the range.

Contact your service representative to replace

 

 

the fan.

0B74

The error occurred during voltage sensor

Contact your service representative.

 

reading.

 

0B75

System voltage out of the range.

 

0B80

BMC Memory Test Failed.

Turn off the power once and then on again to

0B81

BMC Firmware Code Area CRC check failed.

start the server. If the error cannot be

 

 

corrected, contact your service representative.

0B82

BMC core Hardware failure.

0B83

BMC 1BF or 0BF check failed.

 

0B8A

BMC SEL area full.

Start SETUP and select [Server] - [Event Log

 

 

Configuration] - [Clear All Error Logs] and

 

 

press Enter to clear event logs.

0B8B

BMC progress check timeout.

Turn off the power once and then on again to

0B8C

BMC command access failed.

start the server. If the error cannot be

0B8D

Could not redirect the console - BMC Busy -

corrected, contact your service representative.

0B8E

Could not redirect the console - BMC Error -

 

0B8F

Could not redirect the console - BMC

 

 

Parameter Error -

 

0B90

BMC Platform Information Area corrupted.

 

0B91

BMC update firmware corrupted.