8-10

Troubleshooting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error

 

Error message

Recommended Action

code

 

 

 

 

 

 

0B92

 

Internal Use Area of BMC FRU corrupted.

This is not a fatal error. Turn off the power

 

 

 

once and then on again to restart the server. If

 

 

 

the error cannot be corrected, contact your

 

 

 

service representative.

0B93

 

BMC SDR Repository empty.

Turn off the power once and then on again to

 

 

 

restart the server. If the error cannot be

 

 

 

corrected, contact your service representative.

0B94

 

IPMB signal lines do not respond.

This is not a fatal error. Turn off the power

 

 

 

once and then on again to restart the server. If

 

 

 

the error cannot be corrected, contact your

 

 

 

service representative.

0B95

 

BMC FRU device failure.

This is not a fatal error. Turn off the power

 

 

 

once and then on again to restart the server. If

 

 

 

the error cannot be corrected, contact your

 

 

 

service representative.

0B96

 

BMC SDR Repository failure.

Turn off the power once and then on again to

0B97

 

BMC SEL device failure.

start the server. If the error cannot be

 

 

 

corrected, contact your service representative.

 

0B98

 

BMC RAM test error.

 

0B99

 

BMC Fatal hardware error.

 

 

 

0B9A

 

Management controller not responding.

Update the RMC firmware. If the error cannot

 

 

 

 

be corrected, contact your service

 

 

 

 

representative.

 

0B9B

 

Private I2C bus not responding.

Turn off the power once and then on again to

 

0B9C

 

BMC internal exception.

start the server. If the error cannot be

 

0B9D

 

BMC A/D timeout error.

corrected, contact your service representative.

0B9E

 

SDR repository corrupt.

 

 

 

0B9F

 

SEL corrupt.

 

 

 

0BB0

 

SMBIOS – SROM data read error.

Contact your service representative.

0BB1

 

SMBIOS – SROM data checksum bad.

 

 

 

8100

 

Memory Error detected in DIMM group #1.

Contact your service representative to replace

8101

 

Memory Error detected in DIMM group #2.

the DIMM in the relevant group.

8102

 

Memory Error detected in DIMM group #3.

 

 

 

8103

 

Memory Error detected in DIMM group #4.

 

 

 

8104

 

Memory Error detected in DIMM group #5.

 

 

 

8105

 

Memory Error detected in DIMM group #6.

 

 

 

8160

 

Mismatch Processor Speed detected on

Contact your service representative.

 

 

Processor 1.

 

 

 

8161

 

Mismatch Processor Speed detected on

 

 

 

 

 

Processor 2.

 

 

 

None

 

Expansion ROM not initialized – PCI Mass

Disable initialization of the optional device

 

 

Storage Controller in slot xx (xx: slot number)

expansion ROM by using the BIOS SETUP

 

 

 

utility (see Chapter 4).

 

 

H/W Configuration of BMC is corrupted.

Use the NEC EXPRESSBUILDER to

 

 

!! Update BMC F/W Configuration by

configure the optional remote management

 

 

configuration tool !!

card (see Chapter 6).

 

 