4-24 Configuring Your Server

Option

Parameter

Description

Your Setting

Power on Delay

[0] - 255

Specify the DC power on delay

 

Time

 

time within the range between 0

 

 

 

and 255 seconds. The time

 

 

 

specified is valid when "Power On"

 

 

 

or "Last State" is specified for AC

 

 

 

LINK.

 

Platform Event

Disabled

This item becomes meaningless

 

Filtering

[Enabled]

when the notification feature of

 

 

 

EXPRESSSCOPE Engine is

 

 

 

enabled.

 

 

 

[

]: Factory-set

The table below shows the operation when the AC power to the server is turn off once and then on again, depending on the setting of "AC LINK."

System status before AC power off

Setting of AC LINK

 

Stay Off

Last State

Power On

 

Operating

Off

On

On

Aborting (DC power being off also)

Off

Off

On

Forced shutdown

Off

Off

On

* Press the power switch continuously for four seconds or longer. This forcibly turns off the power.

IMPORTANT:

„To power on the server from the UPS (Uninterruptible Power Supply), select [Server] - [AC Link] - [Power On].

„If the server is connected to the UPS, set at least 10 seconds delay in the power-on schedule.