Configuring Your Server 4-43

Others

1.Clear Configuration

Clears configuration information. Select "Configure" → "Clear Configuration" from the TOP menu. Executing "Clear Configuration" clears all configuration information on the disk array controller and hard disk drives. The configuration information on all channels of the disk array controller is also cleared.

NOTES:

„When configuration information on the disk array controller and that on the hard disk drive do not match (excluding at replacement of faulty disk array controller), configuration mail fail if you select the configuration information on the disk array controller. In this case, execute "Clear Configuration" to create configuration again.

„LSI Logic Software RAID Setup Utility cannot delete each logical drive. Use MegaRAID Storage Manager instead.

2.Force Online

Puts a hard disk drive being in the FAIL status online.

Select "Objects" → "Physical Drive" → (select hard disk drive) → "Force Online" from the TOP menu.

3.Rebuild Rate

Sets the Rebuild Rate.

Select "Objects" → "Adapter" → "Sel. Adapter" → "Rebuild Rate" from the TOP menu. Available value is between 0% and 100%. Default value (recommended) is 30%.

4.Hard disk drive information Checks hard disk drive information.

Select "Objects" → "Physical Drive" → (select hard disk drive) → "Drive Properties" from the TOP menu.