Utility Commands
615
ProSafe M4100 and M7100 Managed Switches

no rmon hcalarm

This command deletes the rmon hcalarm entry.

Format no rmon hcalarm <alarm number>
Mode
rmon event

This command sets the rmon event entry in the RMON event mib group.

Format rmon event <event number> [description|log|owner|trap]
Mode
None
Log
SNMP Trap
Log and SNMP Trap

no rmon event

This command deletes the rmon event entry.

Format no rmon event <event number>
Mode
Rising-Threshold
Low Value High capacity alarm rising threshold absolute value low. The lower 32 bits of the absolute
value for threshold for the sampled statistics.
Falling-Threshold
High Value High capacity alarm falling threshold absolute value high. The upper 32 bits of the absolute
value for threshold for the sampled statistic.
Falling-Threshold
Low Value High capacity alarm falling threshold absolute value high. The upper 32 bits of the absolute
value for threshold for the sampled statistic.
Rising/Falling/
Rising-Falling High capacity alarm startup alarm that may be sent. Possible values are Rising Alarm, Falling
Alarm or both.
Owner String High capacity alarm owner. The owner string associated with the entry.
Global Config
Global Config
Parameter Description
Event Number Event identifier
Event Type The type of notification that the probe will make about the event. Possible values are:
Global Config
Parameter Description