Orbit™ 2000 Operation and Maintenance Manual | Maintenance |
|
|
MONTHLY
– Tighten and grease all roller chains
ANNUALLY
– Cleaning of the electrical assembly
E L E C T R IC A L
S H O C K
W A R N IN G : Pow er m ust be disconnected to m achine at fused disconnect!
– Dust can be removed by vacuuming the cabinet with a soft brush wand.
W A R N IN G
W A R N IN G : N ever use com pressed air to rem ove dust from the
inside of the electrical cabinet.
–Inspection of the electrical assembly.
–Tightness of terminals
–Circuit breaker wires
–Loose wires
–Protective Circuit inspection
–Check whether protective connectors are tight. Tighten loose connections. The safety of protective circuits may be checked by feeding a current of at least 10 A (50 Hz) from the PELV source for at least 10 seconds. The test is done between the PE terminal and various points that are part of the protective circuit. See EN