Orbit™ 2000 Operation and Maintenance Manual | Installation |
|
|
4.5 Electrical installation
The main plug may be inserted only into a fixed electrical distribution socket, regularly inspected according to appropriate national standards. Prior to the
During the entire time of operation the user is obligated to comply with the requirements of applicable national standards for printing machines, and their electrical wiring.
| EU VERSION | US VERSION |
Nominal voltage | 3 NPE 400 V/230 V 50 Hz | 3 Phase with ground |
|
| 230+/- 10% VAC 60 Hz |
Operating voltage | 24 VDC | 24 VDC |
Power input | 5 kVA | 5 kVA |
Nominal current | 30 Amps | 30 Amps |
Recommended fuses | 25 A gTF 500V | 25 A gTF 500V |
Electrical installation has been designed, manufactured and tested according to EN
The manufacturer of ORBIT 2000 guarantees that the machine complies with interference elimination to a level specified by EN
Repairs, setup, and maintenance may be performed by a technically trained or sufficiently experienced person, who knows how to avoid dangers involved in manipulations with electricity, as stated in EN 60204- 1, article 3.55.
© GBC Films Group January 2001 | Page 4 - 7 |