Orbit Manufacturing 2000 manual Paper release adjustment

Models: 2000

1 139
Download 139 pages 46.42 Kb
Page 139
Image 139

Maintenance

Orbit™ 2000 Operation and Maintenance Manual

 

 

8.2.4 Paper release adjustment

W A R N I N G

CAUTION: Only a qualified service technician may perform this set - up .

W A R N I N G

WARNING: Press the stop button before performing the following set - up procedure!

Proper feeding is obtained by setting the lift and release of the paper for correct timing. For correct feeding, the instant of paper release and the instant of suction must be adjusted precisely. The adjustment is done by turning the slide valve ( p ).

q

The instant of release must be 1.5 to 2 mm before top dead center; suction is adjusted simultaneously. At the moment of suction, the cups are in the rear position and start dropping. The correct position of the slide valve ( q ) is factory adjusted, and is marked by a paint filled drilled hole.

Page 8 - 10

© GBC Films Group January 2001

Page 139
Image 139
Orbit Manufacturing 2000 manual Paper release adjustment