Maintenance | Orbit™ 2000 Operation and Maintenance Manual |
|
|
– The voltage measured between the terminal PE and the test points may not exceed
U =3.3V | for | S= 1.o square millimeters |
U = 2.6V | for | S= 1.5 sq. millimeters |
U = 1.9V | for | S = 2.5 sq. millimeters |
Where U is the largest drop in voltage and
Sis the smallest effective diameter of the protective conductor in the tested branch of the protective circuit.
–The number of measurements of the protective circuit link is given by the requirements of particular regulations and standards valid in the user’s country.
–MAIN DRIVE AND FEED TABLE GEAR DRIVE
– Running in | - 300 hrs | |
– Normal operation | - 400 hrs |
In case of higher demands the ecologically acceptable oil
– VARIATOR
– Running in | - | 10.000 hrs | - oil OTK | 8 to 10 |
– Normal operation | - | 10.000 hrs | - oil OTK | 8 to 10 |