Maintenance

Orbit™ 2000 Operation and Maintenance Manual

 

 

8.1 Maintenance schedule

It is necessary to lubricate and inspect individual parts at regular intervals to prolong the life and ensure the correct functioning of the machine. Safety as described in Section 1 of this manual must be followed when performing any type of maintenance.

DAILY

Check the quantity of condensed water in the air treatment unit.

If the amount in the vessel is higher than 20 mm, release the fluid.

Check the presence of covers and bolts

Check the correct function of sensors

end switches of the feeding table

capacity sensor

sensor protecting the feeding head

control sensors of removable covers

emergency stop push button

Cleaning of the rollers and machine.

EVERY TWO WEEKS

Lubricate and grease with oil or spray all sliders and leading spindles

Clean the cam and grease

Clean and grease guiding rollers