Installation

Orbit™ 2000 Operation and Maintenance Manual

 

 

c/

d/

e/

f/

– The voltage measured between the terminal PE and the test points may not exceed

U =3.3V

for

S= 1.0 square millimeters

U = 2.6V

for

S= 1.5 sq. millimeters

U = 1.9V

for

S = 2.5 sq. millimeters

( U ) is the largest drop in voltage and ( S ) is the smallest effective diameter of the protective conductor in the tested branch of the protective circuit.

Voltage checks

from fused disconnect - 240 VAC +/- 10% 3 phase with ground.

Check each leg, A,B nad C, to ground for proper voltage drop.

Check main line voltage to locking plug connection on the Orbit™2000.

Connect plug from Orbit™2000 to electrical supply.

Perform a safety check of all emergency stops, safety latches and lockouts.

Emergency stop buttons

Safety shields

Power on/ off lockout

Table limit switches

Feeder head protect from pile-up table

Power-up the Orbit™2000 and confirm that the temperature contoller is illuminated.

If the temperature controller is not illuminated, check the E-Stops, safety latches or lockouts for activation.

Check all roatations of motors: Feeder Pile-up, Feeder pile-down, main drive and

compressor/ feeder