Installation | Orbit™ 2000 Operation and Maintenance Manual |
|
|
c/
d/
e/
f/
– The voltage measured between the terminal PE and the test points may not exceed
U =3.3V | for | S= 1.0 square millimeters |
U = 2.6V | for | S= 1.5 sq. millimeters |
U = 1.9V | for | S = 2.5 sq. millimeters |
( U ) is the largest drop in voltage and ( S ) is the smallest effective diameter of the protective conductor in the tested branch of the protective circuit.
Voltage checks
–from fused disconnect - 240 VAC +/- 10% 3 phase with ground.
–Check each leg, A,B nad C, to ground for proper voltage drop.
–Check main line voltage to locking plug connection on the Orbit™2000.
–Connect plug from Orbit™2000 to electrical supply.
Perform a safety check of all emergency stops, safety latches and lockouts.
–Emergency stop buttons
–Safety shields
–Power on/ off lockout
–Table limit switches
–Feeder head protect from
If the temperature controller is not illuminated, check the
Check all roatations of motors: Feeder
compressor/ feeder
Page 4 - 10 | © GBC Films Group January 2001 |