Orbit™ 2000 Operation and Maintenance Manual

Installation

 

 

4.7 Initial inspection

ELECTRICAL

S H O C K

Remove power to the laminator before performing step ( a ) below . Contact with

electrical components while power is supplied can result in injury or death!

a/ Electrical assembly inspection

Component mounting

Terminal security

Wire tightness

Circuit breaker wires

ELECTRICAL

S H O C K

Electrical troubleshooting should be left to qualified GBC service technicians!

Electrical shock hazard!

b/ Protective circuit inspection

The safety of protective circuits may be checked by feeding a current of at least 10 A (50 Hz) from the PELV source for at least 10 seconds. The test is done between the PE terminal and various points that are part of the protective circuit. See EN 60204-1, article 20.2.