Orbit™ 2000 Operation and Maintenance Manual | Installation |
|
|
4.7 Initial inspection
ELECTRICAL
S H O C K
Remove power to the laminator before performing step ( a ) below . Contact with
electrical components while power is supplied can result in injury or death!
a/ Electrical assembly inspection
–Component mounting
–Terminal security
–Wire tightness
–Circuit breaker wires
ELECTRICAL
S H O C K
Electrical troubleshooting should be left to qualified GBC service technicians!
Electrical shock hazard!
b/ Protective circuit inspection
–The safety of protective circuits may be checked by feeding a current of at least 10 A (50 Hz) from the PELV source for at least 10 seconds. The test is done between the PE terminal and various points that are part of the protective circuit. See EN
© GBC Films Group January 2001 | Page 4 - 9 |