Multipoint Wireless Support for the Cisco uBR7200 Series Universal Broadband Router

radio histogram

Defaults

Command Modes

Command History

average

Specifies histogram samples that should be the average of the burst

 

data over all the frequencies.

 

 

number toneVal

Specifies that a particular tone in the burst should be used to report

 

the histogram data.

 

 

update interval

Specifies how often, in seconds, the collected data is printed on the

 

screen.

 

 

sum

Specifies whether to add the data at every update.

 

 

width coarse fine

Specifies the histogram resolution. Coarse is 50 bins and fine is 12

 

bins.

 

 

No default behavior or values.

 

Interface configuration

 

 

 

Release

Modification

 

 

12.0(7)XR

This command was introduced.

 

 

12.1(3)XQ1

Support for multipoint radio modem was added.

 

 

Usage Guidelines A histogram is a collection of statistics sampled over time on a burst-by-burst basis and presented as a function of bins.

The data for the histogram is collected as soon as the command succeeds and continues until either the specification is deleted using the no option, or the specified duration expires. The collected data is printed out to the console at user-specified intervals.

A histogram statistic is created when data is sampled for every burst. For each sampled burst, the count in a specific bin is incremented.

Note There should be no measurable impact or degradation of router performance from running histograms. Cisco recommends that you keep the number of histograms that you are running simultaneously to a minimum, and that you terminate any histograms no longer needed.