Multipoint Wireless Support for the Cisco uBR7200 Series Universal Broadband Router

radio timeline

Defaults

Command Modes

Command History

down-change

Specifies that the threshold condition is met when the negative

 

change of the value being monitored is greater than the threshValue.

 

 

pos-crossing

Specifies that the threshold condition is met when the value being

 

monitored does a positive crossing (positive increase) of the

 

threshValue.

 

 

neg-crossing

Specifies that the threshold condition is met when the value being

 

monitored does a negative crossing (negative increase) of the

 

threshValue.

 

 

postTrigBufMgt

Specifies the position (position 1 or 2) of the trigger in the data

 

collected. If the trigger position is 1, then most of the data collected

 

before the trigger is returned. If the trigger position is 2, most of the

 

data returned is captured after the occurrence of the trigger.

 

 

No default behavior or values.

 

Interface configuration

 

ReleaseModification

12.1(3)XQ1

This command was introduced.

Usage Guidelines

A timeline is a sequence of data values collected for a specified attribute. The amount of data collected

 

 

 

is controlled by the size parameter. The maximum size is 1000 points.

 

 

 

Collection starts as soon as the command succeeds, and continues until the Trigger option occurs or the

 

 

 

radio interface radio tl-stop command is entered.

 

 

 

 

 

 

Note

Histograms and timelines share the same digital signal process (DSP) memory. A total of

 

 

 

10 histograms and timelines can be created on a single DSP. There are a total of 8 locations

 

 

 

for fine histograms and timelines and 5 locations for coarse histograms. The combination

 

 

 

of histograms and timelines must be less than 10.

 

 

 

 

 

 

 

 

 

 

 

 

Examples

The following example shows how to configure a timeline specification. The collection process starts

 

 

 

as soon as the command succeeds. It collects a timeline for sirn-ant1. The timeline is collected on

 

 

 

channel 3. The timeline size is 600 points. The rest of the parameters are optional and the system picks

 

 

 

default values.

 

 

 

UBR04# radio timeline sinr-ant1 3 600

Cisco IOS Release 12.1(5)XM