SuperTrak EX Series User Manual

Examples

config -a auto

config -a expr -ry -p y -c n -sy -t data -l2

ctrl

Usage

ctrl [-a <action>] [-i <ctrlId>] [-c <ctrl count>] [-v] ctrl -a mod [-i <ctrlId>] -s "<list of settings>" ctrl -a clear [-i <ctrlId>] [-t <condition type>]

Summary

The ctrl command displays controller information and changes controller settings.

Options

-a <action>

Specifies the action to perform.

list

(Default) Lists controller information.

mod

Changes controller settings.

clear

Clears controller conditions.

-i <ctrl ID>

Specifies the controller ID. For subsystems with dual

 

controllers, controller ID is required when setting alias of

 

controller.

-c <ctrl count>

Controller count. Required for information on multiple

 

controllers.

-s "<option>=<value>" Specifies which settings to change.

alias=

A user-specified name for the controller.

 

Up to 48 characters long, alpha- numeric characters,

 

blank spaces and underscores. The beginning and

 

ending blank spaces are discarded.

Following setting is shared if there are dual controllers:

coercion=

Enables or disables disk coercion. Disk coercion will

 

truncate the size of the physical drives. Makes different

 

size drives appear to be the same size. For example, a

 

90.1 GB drive would appear as the same size as an 89.8

 

GB drive. Important when using drives of different

 

manufacturers for rebuilds or as hot spares.

enable

 

disable

 

coercionmethod=

The method of coercion.

194

Page 208
Image 208
Promise Technology EX8658, EX8654, EX8650, EX4650 manual Ctrl, Examples