SuperTrak EX Series User Manual

 

Auto-transition will start transitioning on a used revertible

 

spare in the following condition:

 

1. When the rebuild has completed using the revertible

 

spare, and

 

2. When an unconfigured drive is inserted into the slot of

 

the dead drive which the was part of the array. or

 

When a non-revertible spare has been inserted or

 

created, and is applicable to the array.

 

This option affects all arrays on the subsystem.

enable

 

disable

 

mediapatrol=

Verifies the media of the array and/or spares to find bad

 

blocks on physical disks before you use that block. This

 

feature is enabled and disabled on an array basis.

enable

 

disable

 

ReassignedBlock=Threshold value to trigger PDM, when re-assign map exceeds the threshold value

1..512

 

ErrorBlock=

Threshold value to trigger PDM, when number of medium

 

error on the PD exceeds the threshold value.

1..2048

 

<bg task>=<rate>

Background task rates determine what percentage of the

 

IO load on the controller should be dedicated to the

 

background task. A lower number will mean the task

 

takes longer to complete, a higher number will cause the

 

task to complete faster, all other things being equal.

rebuildrate=

Rebuild rate determines the rate at which rebuild will run.

 

(low=25, medium=50, high=75)

low

 

medium

 

high

 

pdmrate=

PDM rate determines the rate at which PDM will run.

 

(low=25, medium=50, high=75)

low

 

medium

 

high

 