SuperTrak EX Series User Manual

Transition is an operation to replace a revertible spare drive currently used in a disk array with an new physical drive, so the reveritible spare can be restored to spare drive status. The destination drive can be an unconfigured drive, a non- revertible global spare, or a non-revertible spare dedicated to the array.

During transition, the data on the revertible spare is transferred to the destination drive while the disk array remains online. After transition, the destination drive becomes the part of the array and the revertible spare is a spared drive once again.

Options

-a <action>

Specifies the action to perform.

list

(Default) Displays the running and paused transitions

 

and their status.

start

Starts a manual transition.

stop

Stops a transition.

pause

Pauses a transition.

resume

Resumes a paused transition.

-d <DA ID>

Specifies the id of disk array which contains the revertible

 

spare drive.

-s <sequence Num>

Specifies the sequence number of the revertible spare

 

drive in the array.

-p <PD ID>

Specifies the physical drive ID of the destination drive.

Examples transit

transit -a start -d 0 -s 2 -p 10 transit -a stop -d 0 -s 2