SuperTrak EX Series User Manual

mod

Modifies settings. Requires the -s option.

locate

Locates an enclosure by flashing its LEDs.

-e <encl id>

Enclosure ID. The default value is 1 if unspecified.

 

For list action, the default is for all enclosures if

 

unspecified.

-s "<option>=<value>"

Specifies the settings to change.

tempwarning=

Enclosure warning theshold temperature, in degrees

 

Celsius.

10..51

 

tempcritical=

Enclosure critical theshold temperature, in degrees

 

Celsius.

52..61

 

ctrltempwarning=

Controller warning theshold temperature, in degrees

 

Celsius.

10..61

 

ctrltempcritical=

Controller critical threshold temperature, in degrees

 

Celsius.

62..71

 

-t <FRU type>

Specifies which type of FRU to locate. Requires -a locate

 

option.

ctrl

Locates the controller.

cooling

Locates the cooling unit. Only works with SAS type

 

enclosure.

psu

Locates the power supply unit. Only works with SAS type

 

enclosure.

-f <FRU id>

Specifies id of FRU to locate. Requires -a locate option.

 

Valid values are 1 and 2.

-v

Verbose mode. Requires -a list option. VPD information

 

is displayed.

Examples

enclosure enclosure -v

enclosure -a mod -s "tempwarning=40,tempcritical=55"

event

Usage

event [-a <action>] [-l <location>] [-i <SeqNo>] [-c <event count>] [-v]

198

Page 212
Image 212