Chapter 16 Using Software Sequencers

Vision Settings

VS-1824 as Master Device

1.Click on “Sync Options...” in the Options menu.

2.Click on “MIDI Time Code” in the pop-up menu next to Receive Sync.

3.Click on “30 fps, non drop” in the pop-up menu next to SMPTE Format.

4.Click on “OK.”

VS-1824 Settings

1.Hold [SHIFT] and press [EXT SYNC].

2.Move the cursor to Sync Source and use the TIME/ VALUE dial to select “INT.”

3.Move the cursor to Sync Gen and use the TIME/VALUE dial to select “MTC.”

4.Move the cursor to Sync MTC Type and use the TIME/ VALUE dial to select “30.”

5.Press [F6 (Exit)], then press [F4 (MIDI)].

6.Move the cursor to Device ID and use the TIME/VALUE dial to select “17.”

7.Move the cursor to MIDI Thru and use the TIME/ VALUE dial to select “Out.”

8.Move the cursor to SysEx Rx and use the TIME/VALUE dial to select “On.”

9.Move the cursor to MMC and use the TIME/VALUE dial to select “Slave.”

10.Press [PLAY (DISPLAY)] to return to the Playlist display.

Click on the Play icon in Vision. The VS-1824 should begin playback in sync with Vision. If not, check the MIDI connections and OMS settings in your computer.

The next example uses MTC, with the VS-1824 controlling the playback of Vision.

Connections

1.Connect the MIDI OUT port of the VS-1824 to the MIDI IN port of your MIDI interface.

Vision Settings

1.Click on “Sync Options...” in the Options menu.

2.Click on “MIDI Time Code” in the pop-up menu next to Receive Sync.

3.Click on “30 fps, non drop” in the pop-up menu next to SMPTE Format.

4.Click on “Remote Start,” so it is checked.

5.Click on “OK.”

VS-1824 Settings

1.Hold [SHIFT] and press [EXT SYNC].

2.Move the cursor to Sync Source and use the TIME/ VALUE dial to select “INT.”

3.Move the cursor to Sync Gen and use the TIME/VALUE dial to select “MTC.”

4.Move the cursor to Sync MTC Type and use the TIME/ VALUE dial to select “30.”

5.Press [F6 (Exit)], then press [F4 (MIDI)].

6.Move the cursor to Device ID and use the TIME/VALUE dial to select “17.”

7.Move the cursor to MIDI Thru and use the TIME/ VALUE dial to select “Out.

8.Press [PLAY (DISPLAY)] to return to the Playlist display.

Click on the Play icon in Vision, it will start to flash. Press [PLAY] on the VS-1824 and Vision should start playback in sync with the VS-1824. If not, check the MIDI connections and OMS settings in your computer.

Chapter 16

215

Page 215
Image 215
Roland VS-1824 owner manual 215, Vision Settings