Chapter 22 Specific Applications

VS-1824 Settings

1.Hold [SHIFT] and press [F5 (SYSTEM)]. The System Menu appears in the display.

If the System Menu does not appear, press [F6 (EXIT)].

2.Press [F4 (MIDI)].

If “MIDI” does not appear above [F4], press [PAGE] until “MIDI” appears, then press [F4 (MIDI)].

3.Use [ ], [ ], [ ], and [ ] to move the cursor and use the TIME/VALUE dial to make settings for each parameter as described below.

Device ID

For this application, set this to “17.”

MIDI Thru (MIDI Thru Switch)

For this application, set this to “OUT.”

SysEx.Tx (System Exclusive Transmit Switch)

For this application, set this to “On.”

MMC (Midi Machine Control Mode)

For this application, set this to “MASTER.”

Control Type (Mixer Control Types)

For this application, set this to “Off.”

4.Hold [SHIFT] and press [EXT SYNC].

5.Use [ ], [ ], [ ], and [ ] to move the cursor and use the TIME/VALUE dial to make the settings as described below.

Sync Source

For this application, set this to “INT.”

Sync Gen. (Generator)

For this application, set this to “MTC.”

Sync MTC Type (MTC Type)

For this application, set this to “30.”

6.Press [PLAY (DISPLAY)] to return to the Playlist display.

VS-880/880EX Settings

1.Press [SYSTEM] until “SYS MIDI PRM?” is displayed and press [YES/ENTER].

2.Press the PARAMETER RIGHT button until “SYS EX RX” is displayed and use the TIME/VALUE dial to select “ON.”

3.Press the PARAMETER RIGHT button until “MMC =” is displayed and use the TIME/VALUE dial to select “SLAVE.”

4.Press the PARAMETER RIGHT button until “OUT/ THRU =” is displayed and use the TIME/VALUE dial to select “OUT.”

5.Press [SYSTEM] until “SYS SYNC/TEMPO” is displayed and press [YES/ENTER].

6.Use the TIME/VALUE dial to select “EXT.”

7.Press the PARAMETER RIGHT button so that “MTC TYPE” is displayed and use the TIME/VALUE dial to select “30.”

8.Press [PLAY (DISPLAY)] to return to the main screen.

When you press PLAY on the VS-1824, both units will start playing. The VS-1824’s stereo mix output will now contain audio from both units.

You can also use this method to transfer digital audio between the two VS recorders. Connect the DIGITAL OUT of the master VS to the DIGITAL IN of the slave VS—since the MTC generated by the master VS provides synchronization to both VS recorders, its digital output must also supply digital clock to the slave VS.